Designer Waveforms: Ultrasonic Technologies to Improve Cleaning and Eliminate Damage (p. 14)
previous page next page
Applying the Technology (continued)
Figure 15 shows the percent particle removal versus the reciprocal of particle size for five different center frequencies. The exposure time at each frequency is chosen to give 100% removal for a range of particle sizes around the optimum value for that frequency. The sixth graph in figure 15 is the sum of the 40 kHz, 72 kHz 104 kHz and 170 kHz graphs. It shows that a wide range of particle sizes can be efficiently removed by scanning through multiple frequencies.
Figure 15
The first five graphs show particle removal for various ultrasonic frequencies. The sixth graph shows the wide range of particle removal that results from the use of multiple frequencies.